    For Solvent Washout :

    Applications :

    Recovering Unit For Any Environment Chemical Printing Industry , medical Industry

    General explanation :

    This Recycling Unit Designed for Flexographic Photopolymer Plate makers. With Use of Solvent washout chemical and any ecological green chemical with specialties of distilling and cooling with cold air circulation and drain out of residue for high speed revival. Also Can be connected with in-line processor and any plate washout machine directly. Equipped with air-cooling / circulation and drain off the residue directly from a valve. Excellent recovering rate in the shortest time. It is perfect and high efficient recovery unit for flexography.

    Solvent Recovery Systems advantages :

    Reduce your solvent disposal costs and wastewater treatment surcharges 1 year or better payback on most solvent recycling units Equipment sized to meet the needs of small users, and the largest industrial plants.


    With new, used, and refurbished options, we can usually find a system to fit your budget. Technical help with setting up and training to use the solvent recycling systems We won’t forget you after the sale.
    # Technical information

    Recovery volume : 30 / 60 liters
    Power consume : 220V 4.65KW
    Diathermic oil : 15 KG
    Machine dimension :Main body: 1100x780x1200mm
    Recovery rate : 85%


    Solvent Recovery Systems advantages :

    • Reduce your solvent disposal costs and wastewater treatment surcharges
    • 1 year or better payback on most solvent recycling
    • Equipment sized to meet the needs of small users, and the largest industrial plants.
    • With new, used, and refurbished options, we can usually find a system to fit your budget.
    • Technical help with setting up and training to use the solvent recycling systems
    • We won’t forget you after the sale.

    # Operating steps

    After opening the crate, plug in 220 V power, and connect the ground (earth).
    Open the lid and fill the tank up to the level with solvent to be recovered (80 L) Close the lid and tighten it.
    Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
    Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C.
    Vacuum tank pressure(3) high at 0.03 Mpa / low at 0.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
    Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
    If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).

    # Important

    Install the unit in a wide and ventilated place
    Disconnect electric power before doing any action
    No taking off the control panel
    Change the diathermic oil every 1000 working hours
    No filling the solvent container up over the level (80 liters)
    Remove the waste after every recovery process
    Recovery Time 3 o 4 hours

    Model

    Voltage Power Dimension / MM Oil / Kg N/W Kg Capacity / L
    FIP 60L-RHB 60 380V,50Hz,4.65Kw 1080×750×1200 23 120
    FIP 80L-RHB 80 380V,50Hz,4.65Kw 1110×780×1450 25 180
    FIP 200L-RHB 200 380V,50Hz,9.5Kw 1400×980×1430 65 400